Recommendation: 202105-04

back to recommendations listing

Ref # 202105-04
Status Closed
Occurrence Overhead Line detachment, Pearse Station, 1st October 2020
Occurrence Date 01 October 2020
Date Closed 29/03/2023

Basis for Recommendation

The compliance checks on the Electrical Multiple Unit fleet did not include the checking of pantographs.

Recommendation

Iarnród Éireann Railway Undertaking, Chief Mechanical Enginner's Department to include requirements to check pantograph maintenance activities in the Compliance Coordinators documentation records / check sheets.